*Supercarb™ Sterasyl microfilter plus carbon block core |
*Ultracarb™ Stera syl microfilter plus carbon block core and heavy metal rmoval media |
|
| DOULTON CERAMIC CARTRIDGE |
|
|
|
|
|
|
Bacteria removal down to 0.5micron including: 可滤除所有0.5微米病菌的能力,包括:
|
|
|
|
E Coli (大肠杆菌)
|
>99.9%
|
>99.9%
|
|
Vibrio cholera (霍乱菌)
|
>99.9%
|
>99.9%
|
|
Shigella (痢疾志贺氏菌)
|
>99.9%
|
>99.9%
|
|
Salmonella typhi (沙门氏菌)
|
>99.9%
|
>99.9%
|
|
Klebsiellaterrigena (克雷白氏杆菌)
|
>99.9%
|
>99.9%
|
|
|
Typical organic contaminant (过滤有机体性能) removal after 3,000L
|
|
|
|
Herbicides@1.2ppb presence (农药)
|
85%
|
85%
|
|
Insecticides@0.1ppb presence(杀虫剂)
|
85%
|
85%
|
|
Phenols@1.2ppb presence (石碳酸)
|
50%
|
50%
|
|
Trihalomethanes@150ppb presence (甲烷)
|
50%
|
50%
|
|
Poly Aromatic Hydrocarbons@0.2ppb presence(多环芳烃)
|
>95%
|
>95%
|
|
|
|
|
Free chlorine removal (氯气过滤比率)
|
|
|
|
2mg cl/l and 0.6ppm TOC after 8,000L
|
90%after 2600
|
97%after 2600
|
|
2mg cl/l and 2.5ppm TOC after 5,000L
|
No data
|
No data
|
|
2mg cl/l and<0.6ppm TOC after2,000L
|
>95%
|
>95%
|
|
|
Lead removal (重金属过滤比率)
|
|
|
|
IUC@pH6.5 after 3,750L@pH8.5 after 3,750L
|
N/A
|
>98.3%
|
|
UCC@pH6.5 after 2,244L@pH8.5 after 2,244L
|
N/A
|
>98.3%
|
|
|
|
|
Minimum working pressure ( in bar ) 自来水源最低要求水压
|
1 bar
|
1 bar
|
|
Working flow rate ( l/min@2 bar )滤出水流量(每公升/分钟@2 bar)
|
1.9
|
1.9
|
|
Working temperature range Degress’C ( 操作温度-摄氏)
|
5-38
|
5-38
|
|
Working pH range ( 操作酸碱度)
|
5.5-9.5
|
5.5-9.5
|
|
Typical surface area of activ ated carbon per element m' ( 活性碳表面积) ( 平方米 )
|
85.000m2
|
|
|
Recommen ded change frequency ( for 4 users ) 滤芯更换期 ( 4人家庭 )
|
9months or 3‚740L
|
9 months or 2.244L
|